摘要 文章结合静电除尘系统电源改造案例,分析高效电源在火电除尘系统应用效果,阐述了工频电源与高效电源组合应用,在实现烟尘超低排放目标前提下,兼顾投资效益与节能目标。 Combining with the case of electrostatic dust removal system power supply transformation,this paper analyzes the application effect of high-efficiency power supply in thermal dust removal system,expounds the combination application of power frequency power supply and high-efficiency power supply,and gives consideration to the investment benefit and energy saving target under the premise of realizing ultra-low emission of dust.
作者 范圣业 Fan Sheng-ye
出处 《电力系统装备》 2021年第14期110-112,共3页 Electric Power System Equipment
关键词 超低排放 高效电源 高比电阻 ultra-low emission high efficiency power supply high resistance