用于离子迁移谱仪的非放射性电离源的研究进展

Research progress of non-radioactive ionizaiton source for ion mobility sepctrometry
下载PDF
导出
摘要 离子迁移谱技术(IMS)具有灵敏度高、分析速度快、能耗低、易于小型化并且工作在大气压下等特点,被广泛应用于对毒品、爆炸物和化学战剂等毒害物质的检测和鉴定。该文对离子迁移谱仪的工作原理和产物离子产生过程进行了简要介绍,重点讲述了用于离子迁移谱仪的非射性电离技术,及非放射性电离源未来的发展趋势。 Ion mobility spectrometry(IMS)has the characteristics of high sensitivity,fast analysis,low energy consumption,easy miniaturization and atmospheric consumption,easy miniaturization and atmospheric pressure.It is widely used in the poisonous substances such as drugs,explosives and chemical warfare agents detection and identification.In this paper,the working principle of ion mobility spectrometer and the progress of product ion generation are briefly introduced.The non-ionizing ionization technique used in ion mobility spectrometer and the future development trend of non-radioactive ionization source are mainly described.
作者 杨俊超 杨柳 杨杰 张根伟 赵将 曹树亚 Yang Jun-chao;Yang Liu;Yang Jie;Zhang Gen-wei;Zhao Jiang;Cao Shu-ya(State key Laboratory of Nuclear,Biological and Chemical Protection for civilian,Beijing 102205,China)
出处 《化学传感器》 CAS 2020年第1期46-53,共8页 Chemical Sensors
关键词 离子迁移谱 非放射性 电离源 ion mobility spectrometry non-radioactive ionization source
  • 相关文献

参考文献2

二级参考文献87

  • 1[26]Ewing,R.G.;Atkinson,D.A.;Eiceman,G.A.;Ewing,G.J.,A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds,[J]Talanta 2001,54,515-529.
  • 2[27]Karpas,Z.,Ion mobility spectrometry in forensic science,[B]Encyclopedia of Analytical Chemistry,John Wiley & Sons,London,2000.
  • 3[28]Ruzsanyi,V.;Sielemann,S.;Baumbach,J.I.,Determination of VOCs in human breath using IMS[J]Int.J.Ion Mobility Spectrom.2002,5,45-48.
  • 4[29]Eiceman,G.A.;Shoff,D.B.;Harden,C.S.;Snyder,A.R;Martinez,P.M.;Fleischer,M.E;Watkins,M.L.,Ion mobility spectrometry of halothane,enflurane and isoflurane anesthetics in air and respired gases,[J]Anal.Chem.1989,61,1093-1099.
  • 5[30]Xie,Z.;Sielemann,S.;Schmidt,H.;Li,F.;Baumbach,J.I.,Determination of acetone,2-butanonc,diethyl ketone and BTX using HSCC-UV-IMS,[J]Anal.Bio-anal.Chem.2002,372,606-610.
  • 6[31]Karpas,Z.;Chaim,W.;Tilman,B.;C,dalevsky,R.;Lorber,A.,Diagnosis of vaginal infections by ion mobility spectrometry,[J]Int.J.Ion Mobility Spectrom.2002,5,49-54.
  • 7[32]Karpas,Z.;Chaim,W.;Gdalevsky,R.;Tilman,B.;Lorber,A.,A novel application for ion mobility spectrometry:diagnosing vaginal infections,[J]Anal.Chim.Acta 2002,474,115-123.
  • 8[33]Chaim,W.;Karpas,Z.,Lorher,A.,New technology for diagnosis of bacterial vaginosis,[J]European J.Obet.Gynec.Reprod.Biol.2003,111,83-87.
  • 9[34]Snyder,A.P.;Harden,C.S.;Davis,D.M.;Sbeff,D.B.;Maswadeh,W.M.,Hand-portable gaschromatography ion mobility spectrometer for the determination of the freshness of fish,3rd International Workshop on Ion Mobility Spectrometry,Galveston,Texas,October 16 19,1994.pp.146-166.
  • 10[35]Karpas,Z.;Tilman,B.;C,dalevsky,R.;Lorber,A.,Determination of volatile biogenic amines in muscle food by ion mobility spectrometry (IMS),Anal.Chim.Acta 2002,463,155-163.

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部