基于改进恒导通时间控制的临界连续导通模式Boost功率因数校正变换器 被引量:11

Improved Constant On-Time Control of Boundary Conduction Mode Boost Power Factor Correction Converter
下载PDF
导出
摘要 为改善临界连续导通模式(BCM)Boost功率因数校正(PFC)变换器输入电流总谐波畸变率(THD),该文提出一种改进恒导通时间(COT)控制,分析改进COT控制对输入电流THD和变换器效率的影响;通过改进电流过零检测(ZCD)电路实现电感电流过零信号的提前检测,补偿信号传播延时的影响,缩短甚至消除反向谐振过程,改善输入电流THD的同时不增加控制的复杂度。最后,该文搭建一台160W BCM Boost PFC变换器实验样机,验证所提改进COT控制的可行性和有效性。 In order to obtain low input current total harmonic distortion(THD)of boundary conduction mode(BCM)Boost power factor correction(PFC)converter,an improved constant on-time(COT)control is proposed in this paper,and its influence on input current THD and efficiency is also analyzed.Furthermore,an improved zero-current-detection(ZCD)method is adopted to realize the early detection for ZCD signal.The influence of signal propagation delay is compensated,and the reverse resonance process is shortened or even eliminated,thereby improving the input current THD without increasing control complexity.Finally,an experimental prototype of a 160W BCM Boost PFC converter is established to verify the feasibility and effectiveness of improved COT control.
作者 周玉婷 吴羽 任小永 陈乾宏 张之梁 Zhou Yuting;Wu Yu;Ren Xiaoyong;Chen Qianhong;Zhang Zhiliang(Jiangsu Key Laboratory of New Energy Generation and Power ConversionNanjing University of Aeronautics and Astronautics,Nanjing 211106 China)
出处 《电工技术学报》 EI CSCD 北大核心 2021年第20期4329-4338,共10页 Transactions of China Electrotechnical Society
基金 国家自然科学基金资助项目(51777093)。
关键词 恒导通时间控制 无谐振 电流过零检测 临界连续模式 功率因数校正 Constant on-time(COT)control no resonance zero-current-detection(ZCD) boundary conduction mode(BCM) power factor correction(PFC)
  • 相关文献

参考文献5

二级参考文献35

共引文献64

同被引文献74

引证文献11

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部