摘要
S500M钢板整炉探伤不合格,严重影响了企业效益。以58 mm厚度探伤不合格钢板为研究对象,利用金相显微镜、万能拉伸机对金相组织、拉伸断口进行检测分析。结果表明:板厚1/2处的氢致裂纹是导致探伤不合格的主要原因。通过冶炼工艺的优化改进,消除了钢板因整炉探伤不合格报废的现象。
The disqualifcation of S500M steel plate severely affects the enterprise's benefits.Taking the disqualified steel plate of 58 mm thickness as a research object,tests and analysis are performed on metallographic structure,tensile fracture by metallographic microscope and universal tensile tesing machine.The results show that the hydrogen induced cracking at 1/2 plate thickness position is the major cause.After optimizing the melting process,the rejection phenomenon of disqualified steel plate from entire heat in flaw detection is eliminated.
作者
闫献民
毕应
殷懿
Yan Xianmin;Bi Ying;Yin Yi(HBIS Group Wusteel Company)
出处
《宽厚板》
2021年第5期39-41,共3页
Wide and Heavy Plate
关键词
S500M
整炉探伤不合格
氢致裂纹
S500M
Disqualification of entire heat in flaw detection
Hydrogen induced cracking