摘要 There are two connection modes between escalator step and step drive chain of outer roller,connector type A and type B.Connector type B after a period of running was found that the fixing bolt on the connector has loosened,which causes safety risks.In order to eliminate this security issue,the finite element modeling is proposed to analyze the relationship between the force generated by the connector type A or type B during the step band running and the assembly clearance or the assembly mode.So as to find out the root cause of fixing bolt loosening phenomenon,by redesigning the assembly clearance between the connector shaft and the chain hole,the fixing bolt of the connector is prevented from loosening during the step band running,ensuring the safe operation of escalators to avoid injury accidents.
作者 WU Jianlong
机构地区 KONE Elevator Co.
出处 《International Journal of Plant Engineering and Management》 2021年第3期150-166,共17页 国际设备工程与管理(英文版)