摘要
目的建立同时测定泌炎宁颗粒中绿原酸、蒙花苷含量的反相高效液相色谱法。方法色谱柱为ACE Excel C_(18)柱(250 mm×4.6 mm,5μm),流动相为乙腈-0.1%磷酸水溶液(梯度洗脱),流速为1.0 m L/min,检测波长为334 nm,柱温为30℃,进样量为10μL。结果绿原酸、蒙花苷质量浓度分别在11.33~135.91μg/m L(r=0.9992,n=5)和5.48~65.75μg/m L(r=0.9990,n=5)范围内与峰面积线性关系良好;精密度、稳定性、重复性试验的RSD均小于2.0%;平均加样回收率分别为99.44%和99.31%,RSD分别为1.87%和5.34%(n=9)。结论该方法操作简便,重复性好,准确度高,可用于同时测定泌炎宁颗粒中绿原酸、蒙花苷的含量。
Objective To establish a reverse phase-high performance liquid chromatography(RP-HPLC)method for the simultaneous determination of chlorogenic acid and buddleoside in Miyanning Granules.Methods The chromatographic column was ACE Excel C_(18) column(250 mm×4.6 mm,5μm),the mobile phase was acetonitrile-0.1%phosphoric acid aqueous solution(gradient elution),the flow rate was 1.0 m L/min,the detection wavelength was 334 nm,the column temperature was 30℃,and the injection volume was 10μL.Results Chlorogenic acid and buddleoside showed a good linear relationship in the ranges of 11.33-135.91μg/m L(r=0.9992,n=5)and 5.48-65.75μg/m L(r=0.9990,n=5),respectively.The RSDs of precision,stability and repeatability tests were less than 2.0%.The average recoveries of chlorogenic acid and buddleoside were 99.44%and 99.31%with RSDs of 1.87%and 5.34%(n=9),respectively.Conclusion The method is simple,reproducible and accurate,which can be used for the simultaneous determination of chlorogenic acid and buddleoside in Miyanning Granules.
作者
李庆德
蓝献泉
郑锦坤
冯波
陈华龙
彭晶
LI Qingde;LAN Xianquan;ZHENG Jinkun;FENG Bo;CHEN Hualong;PENG Jing(Yuebei People's Hospital,Shaoguan,Guangdong,China 512026;Shaoguan Institute for Food and Drug Control,Shaoguan,Guangdong,China 512028)
出处
《中国药业》
CAS
2021年第20期81-83,共3页
China Pharmaceuticals
基金
广东省韶关市卫生计生科研项目[Y18080]
广东省韶关市科技计划项目[2019sn125]。