摘要
线性滴定法是五十年代初由Gran首先提出的一种新的容量分析法,六十年代后期,Ingman-Johansson等人的改进使其更臻完善,本文将该法引入镀铬液的分析中,取得了令人满意的结果。
A new method for the complete analysis of chromium electroplating solution is described. Only a single acid-base titration was used. Results were calculated by a set of empirical equations,which were deduced by the author.
作者
雍平
汪葆浚
尤大衡
Yong Ping;Wang Baojun;You Daheng(Department of Chemistry,East China Institute of Chemical Engineering,Shanghai)
出处
《高等学校化学学报》
SCIE
EI
CAS
1987年第10期879-881,共3页
Chemical Journal of Chinese Universities