摘要 结合当前中国大唐集团公司中小型水电站设备现状及无人值班评价情况,从设备技术指标、应急技术条件及管理方式提出了提高其可靠性的评价标准,通过对电站现场评价探讨了其改进措施,以期为类似水电站实施无人值班提供借鉴和参考。 Combined with the current equipment status and unmanned evaluation of small and medium hydropower stations in China Datang Corporation Ltd.the evaluation criteria for improving their reliability are proposed from the aspects of equipment technical indicators emergency technical conditions and management mode.The improvement measures are discussed through field evaluation of hydropower stations so as to provide reference for the implementation of similar unmanned hydropower stations.