期刊文献+

690t/h循环流化床锅炉风帽漏渣研究与治理 被引量:1

Research and Treatment of Slag Leakage in the Air Cap of 690t/h Circulating Fluidized Bed Boiler
下载PDF
导出
摘要 本文通过风帽阻力特性数值测试研究,提出了改造方案,风帽整体阻力、风室等压特性良好。开展工程实施,风室与炉膛隔板风阻为5219Pa,阻力适中。消除了风帽漏渣问题,一次风流量可以维持在较低水平,一次风机电流大幅度下降、运行经济性显著增强。 In this paper,through the numerical test of the resistance characteristics of the hood,a modification plan is proposed.The overall resistance of the hood and the isobaric characteristics of the air chamber are good.Carrying out the project implementation,the wind resistance of the air chamber and the furnace partition is 5219Pa,and the resistance is moderate.The problem of slag leakage from the hood is eliminated,the primary air flow can be maintained at a low level,the primary fan current is greatly reduced,and the operating economy is significantly enhanced.
作者 刘建国 LIU Jian-guo(CHN Energy Yili Energy Co.,Ltd.Power Plant,Ordos 014300,China)
出处 《价值工程》 2021年第30期110-112,共3页 Value Engineering
关键词 循环流化床锅炉 风帽 漏渣 治理 circulating fluidized bed boiler wind cap slag leakage treatment
  • 相关文献

参考文献1

二级参考文献11

共引文献10

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部