摘要
在TP质量浓度测定过程中发现2种主要测定分析方法各有优缺点,研究采用一种兼顾两者优点的改良方法,并和连续流动分析法进行对比,做到了过程简化和测定迅速。实验证明,改进后的方法在应急监测中有推广应用的基础。
The advantages and disadvantages of two main analytical methods were found in the determination of TP mass concentration.An improved method considering both advantages was adopted in this study,and compared with the continuous flow analysis method,which simplified the process and made the determination fast.The experimental results showed that the improved method could be popularized and applied in emergency monitoring.
作者
刘耿炜
王璐
华勇
韦爱群
杨鹏程
LIU Gengwei;WANG Lu;HUA Yong;WEI Aiqun;YANG Pengcheng(Yancheng Hydrology and Water Resources Investigation Bureau of Jiangsu Province,Yancheng 224051,China;Sluice Management Institute of Sheyang River,Yancheng 224300,China;Wuxi Hydrology and Water Resources Investigation Bureau of Jiangsu Province,Wuxi 214031,China)
出处
《江苏水利》
2021年第10期13-15,42,共4页
Jiangsu Water Resources
关键词
TP
连续流动分析
小型密封管消解法
质量浓度
TP
continuous flow analysis
small sealed tube digestion method
mass concentration