摘要
简单介绍了上料台架的结构特点及工作原理,针对上料台架机构的缺陷和在应用中出现的问题,分析产生的原因,提出了两种适合现场改造的方案,经计算验证原有设备可以支持改造方案的有效实施,方案简单易行,改造成本低,克服了钢坯砸伤辊道、损坏轴承和减速机的弊病。
Various of structure and disadvantages of charging grid were introduced,and two improved projects were proposed for common structural forms.It has been verified by calculating the original equipment can support the effective implementation of the reform scheme,scheme is simple,the transformation cost is low,it overcomes the malfunctions of billet smashing roller table,bearing and reducer.
作者
潘玉蕊
PAN Yurui(CISDI Thermal&Environmental Engineering Co.Ltd.,Chongqing 401122,China)
出处
《工业加热》
CAS
2021年第10期58-60,共3页
Industrial Heating
关键词
上料台架
下料方式
接料装置
弹性连接
charging grid
feeding way
picking device
elastic connection