摘要 介绍GP-3群孔岩土热响应试验仪原理和试验方法,并对实例项目进行2组(每组4个孔)群孔热响应试验。群孔中单孔岩土热物性参数与这些参数的各孔平均值相比,相对偏差最大达13.71%,而群孔(作为整体)岩土热物性参数与各单孔平均值相比,最大偏差仅2.71%。因此,场地岩土热响应试验孔数量布置太少时地埋管地源热泵系统设计风险较大。对于热响应试验孔数量较多的大型项目群孔热响应试验可提高试验效率。对于小型项目,群孔热响应试验在略增加试验成本(试验工期不变,增大加热功率)的基础上,可大幅提高试验成果的可靠性。 The principle and test method of group bore thermal response tester GP-3 are introduced,and two groups(4 bores in each group)group bore thermal response tests are carried out for the example project.The relative deviations of the thermal physical parameters for individual bore in the group bores is up to 13.71%compared with the average values of these parameters of each bore in the group,while the maximum ones for group bores(as a whole)is only 2.71%.Therefore,the design risk of ground source heat pump system is great when the number of test bores is too small.For large-scale projects with large number of test bores,the test efficiency can be improved with group bore thermal response test,while for small projects,it can greatly improve the reliability of the test results on the basis of slightly increasing the test cost(same test period,greater heating power).
作者 郑雨 段新胜 林清龙 李少华 周士航 Zheng Yu;Duan Xinsheng;Lin Qinglong;Li Shaohua;Zhou Shihang(China University of Geosciences,Wuhan 430074,China;Zhejiang Geological Survey Institute,Hangzhou 310000,China;CCCC Water Resources and Hydropower Construction Co.,Ltd.,Ningbo 315000,China)
出处 《太阳能学报》 EI CAS CSCD 北大核心 2021年第9期422-427,共6页 Acta Energiae Solaris Sinica
关键词 地源热泵 钻孔 导热系数 热物性参数 岩土热响应试验 ground source heat pumps boreholes thermal conductivity ground thermal conductivity thermal response test(TRT)
  • 相关文献

参考文献9

二级参考文献85

共引文献90

同被引文献34

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部