西安200MeV质子应用装置同步环线性光学测量与校正

Linear Optical Measurement and Correction of Synchrotronat Xi’an 200MeV Proton Application Facility
下载PDF
导出
摘要 西安200 MeV质子应用装置(XiPAF)同步环是一个最高运行能量200 MeV的紧凑型同步加速器,测量了XiPAF同步环调束过程中的线性光学函数,并采用基于闭轨响应矩阵(ORM)的方法对线性光学函数进行了校正,得到了校正模型。利用校正模型得到的β函数、色散函数和色品与测量结果符合较好。 Xi’an 200 MeV Proton Application Facility(XiPAF)synchrotron is a compact synchrotron with the maximum operating energy of 200 MeV.The linear optics function in the beam modulation process of XiPAF synchrotron is measured.The linear optics function is corrected based on the closed orbit response matrix(ORM),and the correction model is obtained.βfunction,dispersion function,and chromaticity obtained by using the correction model are in good agreement with the measured results.
作者 杨业 王敏文 叶文博 刘晓宇 李岩 姚红娟 郑曙昕 刘卧龙 王迪 王茂成 赵铭彤 闫逸花 张辉 王百川 吕伟 王忠明 YANG Ye;WANG Min-wen;YE Wen-bo;LIU Xiao-yu;LI Yan;YAO Hong-juan;ZHENG Shu-xin;LIU Wo-long;WANG Di;WANG Mao-cheng;ZHAO Ming-tong;YAN Yi-hua;ZHANG Hui;WANG Bai-chuan;LYU Wei;WANG Zhong-ming(State Key Laboratory of Intense Pulsed Radiation Simulation and Effect,Xi’an 710024,China;Key Laboratory of Particle&Radiation Imaging,Ministry of Education,Beijing 100084,China;Laboratory for Advanced Radiation Sources and Application,Tsinghua University,Beijing 100084,China;Department of Engineering Physics,Tsinghua University,Beijing 100084,China)
出处 《现代应用物理》 2021年第3期92-97,共6页 Modern Applied Physics
基金 国家自然科学基金资助项目(10675074) 国家科技重大专项资助项目(2014ZX01022-301)。
关键词 西安200MeV质子应用装置 同步加速器 线性光学 测量 校正 Xi’an 200MeV Proton Application Facility synchrotron linear optics measurement correction
  • 相关文献

参考文献3

二级参考文献15

  • 1刘桂民,戴志敏,李浩虎,廖怡,徐毅,姜伯承,后接,赵振堂.上海光源储存环磁聚焦结构设计(英文)[J].高能物理与核物理,2006,30(z1):144-146. 被引量:3
  • 2HIRAMOTO K, UMEZAWA M, SAITO K, et al. The synchrotron and its related technology for ion beam therapy[J]. Nucl Instrum Methods B, 2007, 261(1/2): 786-790.
  • 3URSCHUTZ P, CHUBAROV O, EMHOFER S, et al. Status of the SIEMENS particle therapy accelerators[C]// Proceedings of IPAC, Kyoto, 2010.
  • 4TANG S X, GUAN X L, TANG J Y, et al. ATPF-a dedicated proton therapy facility[J]. Chinese Phys C, 2010, 34(3): 383-388.
  • 5BENEDIKT M, WRULICH A. MedAustron-project overview and status[J]. European Physical Journal Plus, 2011, 126(7): 126: 1-11.
  • 6HARBI N A, LEE S Y. Design of a compact synchrotron for medical application[J]. Rev Sci Instrum, 2003, 74(4): 2 540-2 545.
  • 7HOTCHI H, HARADA H, HAYASHI N, et al. Beam loss reduction by injection painting in the 3 GeV rapid cycling synchrotron of the Japan Proton Accelerator Research Complex[J]. Phys Rev ST Accel Beams, 2012, 15(4), 040402.
  • 8JIA Xiaoyu. Physical design of the lowenergy proton sychrotron[D]. Beijing: Tsinghua University, 2013.
  • 9KANG X J. The cooler injector synchrotron at IUCF[D]. Bloomington: Indiana University, 1998.
  • 10LIU H. Design of a compact medical synchrotron and 3D dose delivery of rapid cycling beam[D]. Bloomington: Indiana University, 2013.