摘要
由于有轨电车项目沿线用地紧张,牵引降压变电站选址相对困难。以浙江某地有轨电车项目的箱式变电站为例,分析其标准化方案布置、小型化设备选用以及箱式变电站整体要求,以其为后续同类工程的箱式变电站设计与优化提供借鉴。
Due to the land shortage of tram projects along the line,the site selection for traction step-down substation is rela⁃tively difficult.Taking the box type substation of a tram proj⁃ect in Zhejiang Province as an example,the standardized scheme layout,the selection of miniaturized equipment and the overall requirements for box substation are analyzed,so as to provide a reference for the design and optimization of the box type substation in subsequent similar projects.
作者
朱唯耀
ZHU Weiyao(Shanghai Urban Construction Design&Research Institute(Group)Co.,Ltd.,200125,Shanghai,China)
出处
《城市轨道交通研究》
北大核心
2021年第S02期61-65,共5页
Urban Mass Transit
关键词
有轨电车
牵引降压混合变电站
箱式变电站
小型化设备
tram
traction step-down hybrid substation
box-type substation
miniaturized equipment