文章对断路器和隔离开关的常见故障进行了分析,主要从导电系统过热和断路器危险点等方面进行了论述,提出了防误动检查和线路维修的方法,实现了对断路器和隔离开关检修工作的深入研究,保证了断路器和隔离开关应用的安全性,进一步控制了断路器和隔离开关检修的风险。
Starting from the level of power technology in our country,this article ana-lyzes the common faults of circuit breakers and isolating switches,mainly discusses the overheating of the conductive system and the dangerous points of the circuit breaker,and proposes anti-misoperation inspection and line maintenance.The method realizes in-depth research on the maintenance of circuit breakers and isolat-ing switches,ensures the safety of the application of circuit breakers and isolating switches,and further controls the risks of maintenance of circuit breakers and isolat-ing switches.
出处
《电力系统装备》
2021年第16期84-85,共2页
Electric Power System Equipment
关键词
断路器
隔离开关
检修危险点
circuit breaker
isolating switch
overhaul dangerous points