摘要 为了更好地研究肌肉的收缩运动,介绍了光电容积描记法(PPG)探测肌肉收缩运动的原理,设计了可以同时检测4路信号的反射式光电肌肉收缩传感系统。利用可编程恒流源驱动红外LED,将红外光照射到肌肉组织中,透射出肌肉的光被另外的红外探测电路检测到,并被转换为电信号。在单片机的控制下,4路检测到的电信号通过模拟多路开关实现分时导通,随后分别进行低通滤波和AD采样,最后将得到的4路数据通过蓝牙模块传送到上位机电脑端进行后继处理。电路实现了4路信号的同步探测功能,系统测量准确,性能可靠,具有一定的实用价值。 In order to better study muscle contraction,we introduce the principle of detecting muscle contraction using Photoplethysmography(PPG).An IR muscle contraction sensing system in reflection mode is designed,the system can detect signals from 4 channels at the same time.An IR LED driven by a programmable current source emits IR light into the muscle tissue.The optical detection circuit translates the tiny output light from the muscle into electronic signal.Under the control of MCU,the 4 channels of detected signals are sent to an analog multiplexer,each channel is turned on at different times,and then executed lowpass filtering and AD converting separately.Finally the data of the4 channels is sent to a upper computer through Bluetooth module for further processing.This system have the capability of detecting signals from 4 channels simultaneously,and it is accurate,reliable and useful.
作者 黄剑平 穆瑞珍 林振衡 HUANG Jianping;MU Ruizhen;LIN Zhenheng(School of Opto-Electronic and Communication Engineering,Xiamen University of Technology,Xiamnen Fujian 361024,China;Fujian Provincial Key Laboratory of Modern Precision Measurement and Laser Nondestructive Detection,Putian University,Putian Fujian 351100,China)
出处 《电子器件》 CAS 北大核心 2021年第5期1254-1259,共6页 Chinese Journal of Electron Devices
基金 福建省中青年教师教育科研项目(科技类)(JAT190673) 莆田学院现代精密测量与激光无损检测福建省高校重点实验室开放课题(2018XKA006)。
关键词 光电传感器 肌肉收缩 光电检测 可编程恒流源 滑动平均滤波 optical sensor muscle contraction optical detect programmable current source moving average filter
  • 相关文献

参考文献3

二级参考文献39

  • 1查理.肌电假手的研究进展[J].国防科技,2007,28(9):6-13. 被引量:14
  • 2Chen Z W, Hu T P. A Reconstruct Digit by Transplantation of a Second Toe for Control of an Electromechanical Prosthetic Hnd [ J ]. Microsurgery,2002,22 : 5 - 1 0.
  • 3Calder K M, Stashuk D W, Mclean L. Motor Unit Potential Morphology Differences in Individuals with Non-Specific Arm Pain and Lateral Epicondylitis[ J]. J Neuroeng Rehabil( S1743-0003 ), 2008,5:34-34.
  • 4Rainoldi A, Gazzoni M, Casale R. Surface EMG Signal Alterations in Carpal Tunnel Syndrome:A Pilot Study[ J ]. Eur J Appl Physiol ( S1439-6319 ) ,2008,103 (2) :233-242.
  • 5Kamika B, Oishee M, Ananda S K. Multichannel Fused EMG Based Biofeedback System with Virtual Reality for Gait Rehabilitation[C]// Proceedings of 4th International Conference on Intelligent Human Computer Interaction. Kharagpur ,India,2012:1-6.
  • 6Javad H, Evelyn M, Parvin M, et al. EMG-Force Modeling Using Parallel Cascade Identification [ J ]. Journal of Electromyography and Kinesiology,2012,22:469-477.
  • 7Wonkeun Y, Jung K. Estimation of Elbow Flexion Force during Isometric Muscle Contraction from Mechanomyography and Electro- myography[ J]. Med Biol Eng Comput ,2010,48 : 1149-1157.
  • 8Javad H, Evelyn M, Parvin M, et al. Enhanced Multi-Site EMG- Force Estimation Using Contact Pressure[ C ]//Annual International Conference of the IEEE EMBS ,2012,34:3098-3101.
  • 9Ahsan MR, Ibrahimy MI, Khalifa OO. EMG signal classifi- cation for human computer interaction: a review[J]. Europe- an Journal of Scientific Research, 2009, 33(3): 480--501.
  • 10Aso S, Sasaki A, Hashimoto H, et al. Driving electric car by using EMG interface[C]//Cybernetics and Intelligent Sys- tems, 2006 IEEE Conference on. IEEE, 2006: 1--5.

共引文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部