期刊文献+

运行参数对级联有阀线性压缩机的影响分析 被引量:1

Analysis of operating parameters on cascaded valved linear compressors
下载PDF
导出
摘要 大压比有阀线性压缩机为JT节流制冷机提供稳定的气源以及获取低温所需的压力,为了获得两级耦合的关键运行参数(运行频率、活塞行程、充气压力)对级联压缩机输出特性的影响,开展了相应的研究与测试。搭建了两级压缩机耦合实验台,通过改变工况条件,获得了两级压缩的输出特性:在运行频率均为40 Hz,满行程工作在0.215 MPa的充气压力下,获得了7.12的压比,8 mg/s的质量流量,压缩机效率为17.1%。 The valved linear compressor can provides stable helium gas with high pressure ra-tio for JT refrigerator.To obtain the influence of the key operating parameters(operating frequen-cy,piston stroke,charging pressure)on the output characteristics of the cascade valved linear compressors,the corresponding research and test are carried out.A two-stage valved linear com-pressors test platform is built.By changing the working conditions,the output characteristics of two-stage compression are obtained.Both of the two compressors operate at the frequency of 40 Hz and charging pressure of 0.215 MPa with full piston stroke.A pressure ratio of 7.12 and mass flow of 8 mg/s can be obtained with a compressor efficiency of 17.1%.
作者 丁磊 张华 沙鑫权 蒋珍华 刘少帅 吴亦农 Ding Lei;Zhang Hua;Sha Xinquan;Jiang Zhenhua;Liu Shaoshuai;Wu Yinong(School of Energy and Power Engineering,University of Shanghai for Science and Technology,Shanghai 200093,China;Shanghai Institute of Technical Physics,Chinese Academy of Science,Shanghai 200083,China)
出处 《低温工程》 CAS CSCD 北大核心 2021年第5期12-17,共6页 Cryogenics
基金 国家自然科学基金项目(51806231) 中国科学院战略性先导科技专项(B类)(XDB35000000) 上海市自然科学基金(No.18ZR1445600) 中国博士后科学基金资助项目(2018M630476)。
关键词 液氦温区 有阀线性压缩机 两级压缩 运行参数 输出特性 liquid helium temperature region valved linear compressor two-stage compres-sion operation parameters output characteristic
  • 相关文献

参考文献4

二级参考文献25

  • 1金新,冯小宁.氦气转换曲线与转换温度的讨论[J].低温与特气,1987,5(3):22-25. 被引量:3
  • 2宋金良,吴亦农.微型斯特林制冷机用线性压缩机研究[J].流体机械,2006,34(3):4-6. 被引量:6
  • 3谢英柏,桂良明,徐周璇,黄秀芝.动圈式线性压缩机空载运动特性分析[J].流体机械,2007,35(11):34-36. 被引量:3
  • 4Shinozak K, Sugita H, Sato Y, et al. Developments of 1-4 K class space mechanical coolers for new generation satellite missions in JAXA. In: R G Ross, Jr., ed. Proceedings of the 16th International Cryocooler Conference. Atlanta: Cryocoolers 16, ICC Press, Boulder Colorado, 2010. 1-8.
  • 5Inatani J, Noguchi T, Shi S C, et al. A Submillimeter SIS receiver cooled by a compact stirling-JT refrigerator. In: Blundell R, Tong E,eds. Proceedings of the Eighth International Symposium on Space Terahertz Technology. Cambridge, 1997.273-280.
  • 6Bakos G C, Ioannidis I, Tsagas N F, et al. Experimental and numeri- cal study on a miniature Joule-Thomson cooler for steady-state char- acteristics. Int J Heat Mass Transfer, 2002, 45:609-618.
  • 7Olson J R, Moore M, Champagne P, et al. Development of a space- type 4-stage pulse tube cryocooler for very low temperature. Adv Cryogenic Eng, 2006, 823:623-631.
  • 8Petach M, Durand D, Michaelian M, et al. MIRI cooler system design update. In: R G Ross, Jr., eds. Proceedings of the 16th International Cryocooler Conference. Atlanta: Cryocoolers 16, ICC Press, Boulder Colorado, 2010.9-12.
  • 9Goicoechea J R, Nakagawa T, SPICA team. SPICA: The next generation Infrared Space Telescope. arXiv: 1101.1418 (astro-ph.1M), Accessed 7 Jan 2011.
  • 10Orlowska A H, Bradshaw T W. Closed cycle coolers for space applications. Space Sci Rev, 1992, 61: 233-240.

共引文献25

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部