摘要
对广州市某商场的空调系统主机能效,冷冻水泵、冷却水泵效率,空调器风量、水量进行了实测,根据现场实测结果,分析了商场空调系统存在的问题,并提出了一些节能改造建议。
This paper proposes the detection results of a Commercial building’s air-conditioning system,analyzes some problems of the air-conditioning system,based on the detection results,we put forward some useful suggestions to solve the air-conditioning system problems of this Commercial building.
作者
郭林文
郭勇
屈永强
GUO Linwen;GUO Yong;Qu Yongqiang(Guangdong Architectural Design and Research Institute Co.Ltd,GuangZhou 510010)
出处
《制冷》
2021年第3期74-78,共5页
Refrigeration
关键词
空调检测
能效
改造
Air-Conditioning System Detection
Energy Efficiency
Renovation