期刊文献+

“低压缸零功率”配套的热网加热器增容改造方案

Capacity Increase and Transformation Scheme of Heat Supply Network Heater Matched with"Zero Power of Low Pressure Cylinder"
下载PDF
导出
摘要 针对国产200 MW火力发电机组低压缸零功率改造后,因采暖抽汽流量增加26.8%,导致原有加热器换热面积不足,在原位置加热器增容改造后又无法满足切缸调节蒸汽匹配的问题,对"低压缸零功率"配套的热网加热器进行换型增容改造,保证了低压缸零功率改造后供热输出最大,确保了热网系统的安全稳定运行,提高了机组的运行经济性。 After the zero power transformation of low-pressure cylinder of domestic 200 MW thermal power generating unit,the heating extraction flow increased by 26.8%,resulting in insufficient heat exchange area of the original heater.After the capacity increase transformation of the heater in the original position,it can not meet the steam matching of cylinder cutting regulation.The type change and capacity increase transformation of the supporting heat network heater of"zero power of low pressure cylinder"ensures the maximum output of heat supply after the zero power transformation of low pressure cylinder,ensures the safe and stable operation of heat network system and improves the economy of unit operation.
作者 徐加鹏 XU Jiapeng(Datang Changchun No.2 Thermal Power Company Limited,Changchun 130031,China)
出处 《吉林电力》 2021年第5期54-56,共3页 Jilin Electric Power
关键词 热网加热器 低压缸零功率 抽汽流量增加 供热 经济性 heat network heater zero power of low pressure cylinder increase of extraction steam flow heating economy
  • 相关文献

参考文献4

二级参考文献4

  • 1宋汉武,陈德昌.火力发电设备技术手册第四卷火电站系统与辅机[M].北京:机械工业出版社,1998.
  • 2谭天恩 麦本熙 丁惠华.化工原理[M].北京:化学工业出版社,2001.129-131.
  • 3中华人民共和国机械行业标准.JB/T7837-1995热网加热器.
  • 4李志刚,孙丽萍,刘嘉新.热网监控系统的设计与实现[J].森林工程,2013,29(4):90-95. 被引量:44