期刊文献+

Comparative analysis of the clinical outcomes between wavefront-guided and conventional femtosecond LASIK in myopia and myopia astigmatism 被引量:5

下载PDF
导出
摘要 AIM:To compare the clinical outcomes of wavefront guided femtosecond LASIK(WFG LASIK)and conventional femtosecond LASIK(NWFG LASIK)in eyes with myopia and myopia astigmatism.METHODS:This was a retrospective,nonrandomized,comparative investigation enrolling 236 eyes of 122 patients(18-50 y)with low&moderate and high myopia.The WFG group including 97 eyes(50 patients)undergone WFG LASIK and the NWFG group including 139 eyes(72 patients)undergone conventional LASIK.Mean efficacy index,high order aberrations(HOAs),pupil size and the quality of visual questionnaire were evaluated 6 mo postoperatively.RESULTS:There is no difference between WFG group(-0.054±0.049 in logMAR)and NWFG group(-0.040±0.056)in uncorrected distance visual acuity(UDVA)postoperatively.The myopia astigmatism is higher in WFG group than that in NWFG group(P<0.05).However,the mean efficacy index(MEI)in the WFG group(1.09±0.106)is better than that in the NWFG group(1.036±0.124;P<0.001).Increased HOAs were observed in NWFG group(0.30±0.196)than that in WFG group(0.146±0.188;P<0.001).The pupil size is larger in WFG group(5.15±0.76 mm)than that in NWFG group(4.32±0.52 mm).The patients are satisfied with the clinical surgery,yet WFG group showed better visual quality using the questionnaire survey.Meanwhile,high myopia would result in worse MEI,HOAs and visual quality than low&moderate myopia.CONCLUSION:WFG and NWFG FS-LASIK are both effective and safe procedures to correct low&moderate and high myopia,but WFG FS-LASIK gives a better postoperative MEI,aberrometric control and predictable outcome.Meanwhile,WFG FS-LASIK is better than NWFG FS-LASIK in correction of myopia astigmatism.Low&moderate myopia allow better clinical outcomes than high myopia using any surgical method.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第10期1581-1588,共8页 国际眼科杂志(英文版)
基金 National Natural Science Foundation of China(No.81800624,No.81700839,No.82171081) the“Chen Guang”Project the Shanghai Municipal Education Commission and the Shanghai Education Development Foundation(No.18CG40) 234 Mountain Climbing Plan of Changhai Hospital(No.2020YXK048,No.2020YXK058) “Sailing Project”Naval Medical University。
  • 相关文献

参考文献1

二级参考文献21

  • 1Yazar S, Hewitt AW, Forward H, McKnight CM, Tan A, Mountain JA, Mackey DA. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors. J Cataract Refract Surg 2014;40(3):441-449.
  • 2Mocko L, Zajac M, Roszkowska AM, Weglarz B, Milka M, Dobrowolski D, Wylega?a E. Contemporary applications of wavefront aberrometry in ophthalmology practice. Klin Oczna 2012;114(1):75-78.
  • 3Madrid-Costa D, Ruiz-Alcocer J, Ferrer-Blasco T, García-Lázaro S, Montés-Micó R. In vitro optical performance of a new aberration-free intraocular lens. Eye (Lond) 2014;28(5):614-620.
  • 4Hiraoka T, Miyata K, Nakamura Y, Ogata M, Okamoto F, Oshika T. Influence of cycloplegia with topical cyclopentolate on higher-order aberrations in myopic children. Eye (Lond) 2014;28(5):581-586.
  • 5Lian Y, Shen M, Huang S, Yuan Y, Wang Y, Zhu D, Jiang J, Mao X, Wang J, Lu F. Corneal reshaping and wavefront aberrations during overnight orthokeratology. Eye Contact Lens 2014;40(3):161-168.
  • 6Lee SH, Chang JW. The relationship between higher-order aberrations and amblyopia treatment in hyperopic anisometropic amblyopia. Korean J Ophthalmol 2014;28(1):66-75.
  • 7Wang L, Wang N, Koeh DD. Evaluation of refractive error measurements of the Wavescan Wavefront system and the Tracey Wavefront aberrometer. J Cataract Refract Surg 2003;29(5):970-979.
  • 8Rodríguez P, Navarro R, González L Hernández JL. Accuracy and reproducibility of Zy wave, Tracey, and experimental aberrometers. J Refraet Surg 2004;20(6):810-817.
  • 9López-Miguel A, Martínez-Almeida L, González-García MJ, Coco-Martín MB, Sobrado-Calvo P, Maldonado MJ. Precision of higher-order aberration measurements with a new Placido-disk topographer and Hartmann-Shack wavefront sensor. J Cataract Refract Surg 2013;39(2):242-249.
  • 10Pinero DP, Juan JT, Alió JL. Intrasubject repeatability of internal aberrometry obtained with a new integrated aberrometer. J Refract Surg 2011;27(7):509-517.

共引文献8

同被引文献24

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部