期刊文献+

某大型水电站准同期并列参数整定分析 被引量:1

Analysisof Quasi-synchronous Paralleling Parameter Setting a Large Hydropower Station
下载PDF
导出
摘要 从水轮发电机同期并列条件出发,以尽量减小水轮发电机组同期合闸瞬间冲击电流为出发点,结合自动准同期工作原理,对同期装置主要参数,包括相角差、频率差、电压差、调压速率、调速速率进行整定分析,整定结果可靠,确保了同期并列时水轮发电机组和电力系统的稳定性。 Based on the synchronous parallel conditions of hydro-generators,settings of major parameters,including phase angle difference,frequency difference,voltage difference,voltage regulation rate,and speed regulation rate in the synchronizing device were analyzed in accordance with the automatic quasi-synchronization principle with a starting point of minimizing the instantaneous surge current of the synchronous closing of hydrogenerator sets.Setting results were proven to be reliable,safeguarding the stability of the hydro-generator unit and the power system in the synchronous parallel process.
作者 李雨通 郭玉恒 王秀梅 LI Yu-tong;GUO YU-heng;WANG Xu-mei(Ertan Hydropower Plant,Panzhihua 617000,China)
机构地区 二滩水力发电厂
出处 《云南水力发电》 2021年第11期266-269,共4页 Yunnan Water Power
关键词 同期并列 冲击电流 参数 整定 synchronous parallel impulse current parameter setting