采用变频串联谐振设备对各类大中型变压器进行交流耐压试验可以有效解决传统耐压设备额定电流不足的问题。但串联谐振试验需要选择合适的电抗器和补偿电容,以保证试验在工频条件下进行。采用神经网络的计算方法,根据试品的电容自动计算出电抗器和补偿电容的组合方案,可以有效减少计算量,提高计算精度,为试验提供便利。
Using variable frequency series resonant equipment to conduct AC withstand voltage tests on various large and medium-sized transformers can effectively solve the problem of insufficient rated current of traditional voltage equipment.But the series resonance test needs to choose a suitable reactor and compensation capacitor to ensure that the test is carried out under power frequency conditions.This article will use the neural network calculation method to automatically calculate the combination of reactor and compensation capacitor based on the capacitance of the sample,effectively reducing the amount of calculation,improving the calculation accuracy,and providing convenience for the test.
作者
沈梦瀛
刘团
丁宇涛
SHEN Mengying;LIU Tuan;DING Yutao(Party Construction Department,Huzhou Power Supply Company,State Grid Zhejiang Electric Power Co.,Ltd.,Huzhou,Zhejiang 313000,China;Substation Maintenance Center,Huzhou Power Supply Company,State Grid Zhejiang Electric Power Co.,Ltd.,Huzhou,Zhejiang 313000,China)
出处
《上海电力大学学报》
CAS
2021年第S01期35-37,共3页
Journal of Shanghai University of Electric Power
关键词
神经网络
串联谐振
变压器
耐压试验
neural network
series resonance
transformer
withstand voltage test