期刊文献+

智能手机红外线热成像系统监测移再植组织微循环的研究进展 被引量:3

Progress in research of monitoring microcirculation of replanted tissue by Smartphone-based thermal imaging system
原文传递
导出
摘要 常规的观察血运的方法不足以在早期发现血管危象,进而影响移再植手术的成功率。红外线热成像技术(IRT)通过直观呈现人体表面温度数值及温度热像图,达到监测移再植组织微循环状况目的。随着科技的快速进步,IRT亦逐渐走向成熟与变革。本文就智能手机红外线热成像系统(SBTI)监测移再植组织微循环的研究进行综述,以期为后续相关研究和临床应用提供依据。 Routine vascular observation is not conducive to the early detection of vascular crisis,thus influencing the success rate of replantation surgery.Infrared thermographic imaging(IRT)can be used to monitor the microcirculation of replanted tissue by visually presenting the value of human surface temperature and thermogram.With the rapid progress of science and technology,IRT technology has gradually become mature and reformed.This article reviewed the research on monitoring microcirculation of replanted tissue by Smartphone-based thermal imaging(SBTI),in order to provide a basis for subsequent research and clinical application.
作者 贾飞飞 韩素琴(综述) 王欣(审阅) JIA Feifei;HAN Suqin;WANG Xin(Department of Hand Surgery,Ningbo 6th Hospital,Ningbo,Zhejiang Province 315000,China)
出处 《中华显微外科杂志》 CSCD 北大核心 2021年第5期595-598,共4页 Chinese Journal of Microsurgery
基金 浙江省自然科学基金(LBY20H180001) 宁波市人社局项目(NBLJ201801038) 宁波市公益计划重大项目(2019C50044) 宁波市鄞州区农业与社会发展科技项目(2019AS0024)。
关键词 智能手机 红外线热成像技术 微循环监测 断指再植 组织重建 Smartphone Infrared thermographic imaging technique Microcirculation monitoring Replantation of severed fingers Tissue reconstruction
  • 相关文献

参考文献5

二级参考文献24

  • 1刘晓芳.断指再植术后发生血管危象的原因分析及处理对策[J].中华显微外科杂志,2005,28(3):274-276. 被引量:105
  • 2樊寻梅.儿科感染性休克(脓毒性休克)诊疗推荐方案[J].中华儿科杂志,2006,44(8):596-598. 被引量:205
  • 3Tsujino Y. An approach for the performance analysis of an uncooled infrared bolometer imager[J]. Infrared Phys Tech, 2010, 53(1 ): 50-60.
  • 4Kruse PW. Uncooled IR focal plane arrays[J]. Proc SPIE Infrared Technology XXI, 1995, 2552: 556-563.
  • 5Ray SF. Scientific Photography and Applied Imaging[M]. Boston: Focal Press, 1999.46-47.
  • 6Scribner DA, Sarkady KA, Kruer MR, et al. Adaptive nonuniformity correction for IR focal-plane arrays using neural networks[J]. Proc SPIE Infrared Sensors: Detectors, Electronics Signal Process, 1991, 1541: 100-109.
  • 7ASTM. ASTM E1543-00, Standard test method for noise equivalent temperature difference of thermal imaging systems[S].
  • 8How is NEDT measured?[R/OL], http://flir.custhelp.com/app/ answers/detail/a_id/128/-/how-is-nedt-measured%3 F.
  • 9Lim CL, Byrne C, Lee JKW. Human thermoregulation and measurement of body temperature in exercise and clinical settings[J]. Ann Acad Med Singap, 2008, 37(4): 347-353.
  • 10Legrand FD, Bertucci WM, Arfaoui A. Relationships between facial temperature changes, end-exercise affect and during-exercise changes in affect: A preliminary study[J]. Europ J Sport Sci, 2015, 15(2): 161-166.

共引文献42

同被引文献39

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部