期刊文献+

静电式空气净化器净化颗粒物性能关系研究 被引量:1

Study on the Relationship between the Performance of Electrostatic Air Purifier to Purify Particulate Matter
下载PDF
导出
摘要 结合当前空气质量现状,针对部分标准及文献结论常提到的净化器洁净空气量与风量和一次通过净化效率隐性关系,依据《GB/T 18801-2015空气净化器》为主思路设计试验,对静电式空气净化器进行测试分析,探讨它们是否成等式关系。结果表明通过风量与一次通过净化效率(PM_(2.5)净化效率或≥0.3μm净化效率)的乘积得到的理论洁净空气量值跟实际值存在9.23%~17.99%范围的相对偏差,而在提升净化器净化效率之后偏差得以进一步降低,达到5.62%~14.76%。因此对于在机器密封性好,进出风方式受颗粒物沉降作用较小的情况下得出的理论计算值有一定的参考意义。 Combined with the current status of air quality,aiming at the hidden relationship between the clean air delivery rate of purifier and the air volume and the one-time purification efficiency often mentioned in some standards and literature conclusions,the test is designed based on the“GB/T 18801-2015 Air cleaner”as the main idea,and the test and analysis of electrostatic air purifier were conducted to explore whether they were equal.The results show that the theoretical clean air delivery rate obtained by the product of air volume and one-time purification efficiency(PM_(2.5) purification efficiency or≥0.3μm purification efficiency)has a relative deviation in the range of 9.23%~17.99% from the actual value,and the deviation can be further reduced after the purification efficiency of the purifier is improved,reaching 5.62%~14.76%.Therefore,it has certain reference significance for the theoretical calculation value obtained under the condition that the machine has good sealing performance and the inlet and outlet wind is less affected by the deposition of particles.
作者 张宇翔 万分龙 徐国洋 杜少平 丁年平 谢琼鑫 Zhang Yuxiang;Wan fenlong;Xu Guoyang;Du Shaoping;Ding Nianping;Xie Qiongxin(Guangzhou Institute of Microbiology Co.,Ltd.,Guangzhou 510663,China)
出处 《广东化工》 CAS 2021年第22期105-106,131,共3页 Guangdong Chemical Industry
关键词 静电式空气净化器 PM_(2.5) 一次通过净化效率 洁净空气量 风量 electrostatic air purifier PM_(2.5) one-time purification efficiency clean air delivery rate air volume
  • 相关文献

参考文献3

二级参考文献19

  • 1鲁建国,张晓.GB/T 18801-2008《空气净化器》与PM2.5的关系探讨[J].家电科技,2013(S1):150-152. 被引量:10
  • 2鹿院卫,马重芳,王伟,常梦媛.几种光催化空气净化器的性能测试分析[J].北京工业大学学报,2005,31(1):58-62. 被引量:14
  • 3KIM Y M, HARRAD S,HAKKISON R M. Concentrations andsources of VOCs in urban domestic and public microenvironments[J]. Environmental Science & Technology, 2001,35(6) : 997 -1004.
  • 4GUO Yunzhi(郭枝).Research on indoor VOC distribution withair c;ean?r(空气净化器存在时室内VOC存:在浓度分布研究)[D]. Beijing; Tsinghua University, 2004.
  • 5SMITH K R. Fuel combustion, air pollution exposure,and health :the situation in developing countries [ J ]. Annual Review of Energyand the Environment, 1993,18( 1 ) : 529 - 566.
  • 6GB/T 18801-2008 Air c/eaner(空气净化器)[S]..
  • 7DENG Gaofeng(邓高峰),TAN Xiaoxia(谭小霞),WANG Hon-gen(王宏,恩),et al. Analysis of several air purifiers purificationeffect [ C]//Beijing Association of Refrigeration(北京制冷学会).Celebration of the 30th Anniversary of the Establishment of BeijingAssociation of Refrigeration and the 10th National Symposium Pro-cedhp (庆祝北京制冷学会成立三十周年暨第十届学术年会论文集).Beijing; Beijing Association of Refrigeration, 2010 :132 -135.
  • 8NOVOSELAC A, SIEGEL J A. Impact of placement of portable aircleaning devices in multizone residential environments[ J]. Build-ing and Environment, 2009 , 44(12) : 2348 -2356.
  • 9REN Shengxiong(任生雄).Investigation on the performance ofairliner cabin air filter and its cleaning efficiency for the airline cab-航空高效过滤器性能研究和机舱净化效果分析〉[D].Tianjin: Tianjin University, 2012.
  • 10THATCHER T L, LAI A C K, MORENO-JACKSON R,et al.Effects of room furnishings and air speed on particle deposition ratesindoors [ J ]. Atmospheric Environment, 2002, 36 (11): 1811 -1819.

共引文献31

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部