PTA装置第三结晶器搅拌器断轴故障分析及处理 被引量:1

Analysis and treatment of shaft breakage of agitator in the third crystallizer of PTA plant
下载PDF
导出
摘要 针对PTA装置的第3结晶器搅拌器在使用过程中经常出现搅拌轴断轴、稳定轴承磨损、拉杆断裂的故障现象,通过分析研究,找出故障原因,提出改进措施,改进后达到预期效果,确保了搅拌器平稳运行。 In view of the failure phenomena of mixing shaft breaking,stable bearing wear and pull rod fracture often occurred in the third crystallizer agitator of PTA unit,through analysis and research,the failure causes were found out and improvement measures were put forward.After improvement,the expected effect was achieved and the smooth and stable operation of the agitator was ensured.
作者 闫一伟 李金路 朱炜 范云翔 冯德贵 YAN Yi-wei;LI Jin-lu;ZHU Wei;FAN Yun-xiang;FENG De-gui(Jiaxing Petrochemical Co.,Ltd.,Jiaxing,314201,China)
出处 《聚酯工业》 CAS 2021年第6期51-53,共3页 Polyester Industry
关键词 PTA装置 搅拌器 搅拌轴 稳定轴承 PTA device agitator mixing shaft stable bearing