期刊文献+

Quick valence analysis method of vanadium toward accurate toxicity assessment of vanadium-containing hazardous wastes 被引量:2

钒的快速价态分析方法及其用于含钒有害废弃物毒性的准确评价
下载PDF
导出
摘要 In order to develop a quick, efficient and sensitive valence analysis method of vanadium(Ⅴ), the highperformance liquid chromatography(HPLC) was utilized to separate and quantify EDTA-complexed Ⅴ(Ⅲ), Ⅴ(Ⅳ) and Ⅴ(Ⅴ) ions. The influence of EDTA, TBAOH, solution pH and organic modifier on retention behavior of V-EDTA complexes was investigated. Complexed Ⅴ(Ⅲ), Ⅴ(Ⅳ) and Ⅴ(Ⅴ) ions can be separated and quantified in 5 min, with detection limits of 0.04 mg/L Ⅴ(Ⅲ), 0.07 mg/L Ⅴ(Ⅳ), and 0.06 mg/L Ⅴ(Ⅴ), respecti vely. The established method is applied to analyzing the hazardous waste of V-Cr-bearing reducing slag and results demonstrate 49.94% of its Ⅴ element to be toxic Ⅴ(Ⅴ). This work opens a new avenue for quick and accurate toxicity assessment of hazardous wastes containing multivalent heavy metals. 为了开发一种快速、高效、灵敏的钒(Ⅴ)价态分析方法,利用高效液相色谱(HPLC)分离和定量EDTA络合Ⅴ(Ⅲ)、Ⅴ(Ⅳ)和Ⅴ(Ⅴ)离子。研究EDTA、TBAOH、溶液pH和有机改性剂对Ⅴ-EDTA络合物保留行为的影响。络合之后的Ⅴ(Ⅲ)、Ⅴ(Ⅳ)和Ⅴ(Ⅴ)离子可在5 min内分离和定量,检测限分别为0.04、0.07和0.06 mg/L。将所建立的方法应用于含钒铬还原渣危险废物的分析,结果表明含钒还原渣中49.94%的钒为有毒钒。这项工作为含多价重金属危险废物的快速、准确毒性评估开辟了新途径。
作者 Hong-yi LI Xin-mian CHEN Dan-qing LI Yun GUO Jiang DIAO Bing XIE 李鸿乂;陈新勉;李丹青;郭赟;刁江;谢兵(重庆大学材料科学与工程学院,重庆400044)
出处 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2021年第11期3602-3613,共12页 中国有色金属学报(英文版)
基金 the National Key Research and Development Program of China (No. 2020YFC1909701) the National Natural Science Foundation of China (No. 52074050) Chongqing Science and Technology Bureau (Nos. cstc2019jcyjjqX0006, cstc2021ycjhbgzxm0075)。
关键词 VANADIUM VALENCE HPLC-UV mass spectrometry EDTA 价态 高效液相色谱-紫外检测法 质谱 乙二胺四乙酸
  • 相关文献

参考文献4

二级参考文献15

共引文献28

同被引文献10

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部