期刊文献+

The Hemodynamic Study on the Effects of Entry Tear and Coverage in Aortic Dissection

下载PDF
导出
摘要 In this work,the hemodynamic effects of the type-A aortic dissection in different entry and covering entry tear positions were mainly studied.It provides a new method or idea in the field of the aortic dissection hemodynamics,and it is of profound significance to provide basic theoretical research on the development of aortic dissection in the aspect of clinical judgment.Two type-A aortic dissection models with different entry tear positions(Model 1:The entry tear was located at the entrance of the ascending aorta,Model 2:The entry tear was located at the starting position of the descending aorta)were reconstructed according to the computed tomography(CT)images of the patients.In our study,the thoracic aortic endovascular repair was simulated by covering the entry tear(Model 3).To clarify the hemodynamic effects of entry tear and coverage,the comparative study on the true lumen(TL)and false lumen(FL)blood flow patterns of three models were carried out numerically.The velocity vector,flow ratio,pressure,time-averaged wall shear stress(TAWSS)and relative residence time(RRT)were calculated to evaluate the hemodynamic changes.The results of this work indicated that(I)the velocity of entry tear at the aorta entrance was higher;(II)The helical development of the TL and FL might be related to the helical nature of aortic arch;(III)The blood flow which passing the FL of Model 1,Model 2 and Model 3 in one cardiac cycle were approximately 26.63%,13.39%and 1%,respectively;(IV)The difference in intima wall pressure of the TL and FL were showed a strong pulsation;(V)The TAWSS distribution in TL and FL were completely different(the TAWSS in TL intima>8 Pa,the TAWSS in FL intima<4 Pa).In brief,the aortic morphology and location of the entry tear were found to have a significant effect on the hemodynamics of the aortic dissection.In addition,the CFD method is used to obtain multi-dimensional hemodynamic information such as velocity field,pressure,TAWSS and RRT,which can help clinicians better understand the development of type-A aortic dissection and provide a theoretical basis for clinical treatment.
出处 《Computer Modeling in Engineering & Sciences》 SCIE EI 2019年第12期929-945,共17页 工程与科学中的计算机建模(英文)
基金 This study was partly funded by the National Natural Science Foundation of China(Grant Nos.11602007,11572014,11832003) the Key research and development program(2017YFC0111104),and New Talent(015000514118002).
  • 相关文献

参考文献1

二级参考文献25

  • 1Sundareswaran KS, De Zelicourt D, Pekkan K, et aL Ana- tomically realistic patient-specific surgical planning of com- plex congenital heart defects using MRI and CFD [ C]// Proceedings of the 29th International Conference of IEEE Engineering in Medicine and Biology Society. Lyon, France: Is. n. ], 2007: 202-205.
  • 2Anderson RH, Cook AC. Morphology of the functionally univentricular heart [ J]. Cardiol Young, 2004, ]4 ( Suppl ! ) : 3-]2.
  • 3Bardo DME, Frankel DG, Applegate KE, et aL Hypoplas- tic left heart syndrome [J]. Radio Graphics, 2001,2](3) : 705 -717.
  • 4Hancock Friesen CL, Forbess JM. Surgical management of the single ventricle [J]. Prog Pediatr Cardiol, 2002, ]6 (1) : 47-68.
  • 5DeGroff CG. Modeling the Fontan circulation: Where we are and where we need to go [ J]. Pediatr Cardiol, 2008, 29(1) : 3-12.
  • 6Hsia TY, Migliavacca F, Pittaccio S, et al. Computational fluid dynamic study of flow optimization in realistic models of the total cavopulmonary connections [ J ]. J Surg Res, 2004, 116(2): 305-313.
  • 7de Zlicourt DA, Pekkan K, Paks J, et al. Flow study of an extracardiac connection with persistent left superior vena cava EJ], J Thorac Cardiovasc Surg, 2006, 13l(4) : 785- 791.
  • 8Biffi M, Boriani G, Frabetti L, et al. Left superior vena cava persistence in patients undergoing pacemaker or cardiovert- er-defibrillator implantation: A ]O-year experience [ J ]. Chest, 2001, 120(1) : 139-144.
  • 9Krishnan U. Univentricular heart: Management options [J]. Indian J Pediatr, 2005, 72(6) : 519-524.
  • 10Sun Q, Wan DW, Liu JF, et aL Patient-specific computa- tional fluid dynamic simulation of a bilateral bidirectional Glenn connection [J]. Med Biol Eng Comput, 2008, 46 (11) : 1153-1159.

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部