摘要
基于冷却器工作原理,提出了空水冷却器实际运行时冷、热风温度求解方法。分析了冷却器带走热量、风量及冷却器的供水量、进水温度等对风温的影响。为电机冷却系统故障分析和智能诊断提供理论依据。
Based on the basic working principle of the cooler,the method to solve the temperature value of cold and hot air under the actual operation of the air-water cooler is put forward and influence by air volume,water flow rate and water inlet temperature on the air temperature of the cooler when it ventilating the heat,is analyzed to provide the basic evidence for fault analysis and intelligent diagnosis of the hydro generator cooling system.
作者
王超
周光厚
张海波
蒋富强
WANG Chao;ZHOU Guanghou;ZHANG Haibo;JIANG Fuqiang(Dongfang Electric Machinery Co.,Ltd.,618000)
出处
《电机技术》
2021年第5期31-36,共6页
Electrical Machinery Technology
关键词
空水冷却器
实际运行
冷、热风温度
变化规律
air-water cooler
actual operation
cold and hot air temperature
change law