摘要 为解决锅炉屏过结焦问题,对锅炉炉膛温度场进行测试。通过对焦块生成机理、燃煤灰成分、焦块成分、灰熔融特性状况进行分析,确认锅炉结焦的原因,并对锅炉运行方式进行调整。调整后锅炉掉焦及屏过结焦问题得到有效缓解。 In order to solve the problem of over-coking of boiler screen,the temperature field of boiler furnace was tested.Based on the analysis of the mechanism of coke formation,the composition of coal ash,the composition of coke and the ash melting characteristics,the cause of the coking of the boiler is confirmed and the operation mode of the boiler is adjusted.After adjustment,the problems of coke drop and screen over-coking of the boiler are effectively alleviated.
作者 刘维岐 汪山入 高文杰 吴炬 宋大勇 张家维 LIU Weiqi;WANG Shanru;GAO Wenjie;WU Ju;SONG Dayong;ZHANG Jiawei(Shenyang Institute of Engineering,Shenyang 110136,China;Shenyang Thermal Engineering Design and Research Institute,Shenyang 110000,China;China Energy Science and Technology Research Institute Co.,Ltd.,Nanjing 210023,China)
出处 《黑龙江电力》 CAS 2021年第5期452-456,共5页 Heilongjiang Electric Power
关键词 超临界锅炉 屏式过热器 过热器结焦 低灰熔点 supercritical boiler platen superheater superheater coking low ash melting point