摘要
探讨一种直观、易于理解且反映雷击放电机理的实验方法,以评价不同类型避雷针的雷击接闪效能差异,对雷电防护领域形成共识显得尤为重要。为此,论文首先分析了雷电环境下地面目标物上避雷针的雷击接闪过程,指出不同类型避雷针接闪效能的差异主要体现在对迎面放电过程的影响上;接着,提出了如下实验评价方法:采用针-板间隙的放电实验布置,对4 m及以上间隙施加1.2/50μs标准雷电波模拟迎面流注放电过程,对6 m及以上间隙施加250/2500μs标准操作波模拟迎面先导放电过程;然后,通过比较非传统避雷针与传统避雷针的放电起始时刻与平均发展速度2个指标,以评价不同类型针的接闪效能差异;最后,利用所提方法对典型提前放电(early streamer emission,ESE)非传统避雷针与传统避雷针开展了接闪效能差异的评价实验。实验结果表明:ESE针与传统避雷针的评价指标基本一致,不具备研发商所宣称的引雷增效作用。
There is an increasing demand for an intuitive and easy-to-understand experimental evaluation method for the lightning attractive efficiency difference of different lightning rods based on the lightning discharge mechanism;however,it is necessary to reach a consensus in the field of lightning protection.The lightning attachment process of rods on grounded objects in a lightning environment was analyzed in this study to illustrate that differences in lightning attractive efficiency are mainly attributable to the upward discharge process.An experimental evaluation method for lightning rod attractive efficiency was developed accordingly.A 1.2/50μs standard lightning impulse wave was applied to the rod electrode with a rod-plate gap of 4 m and above to simulate the upward streamer discharge process,then a 250/2500μs standard switching impulse wave was applied to a gap of 6 m to simulate the upward leader discharge process.The performance of a non-conventional lightning rod and a conventional lightning rod was compared in terms of inception time and average propagation speed.An experiment was carried out to evaluate the lightning attractive efficiency difference between the typical non-conventional lightning rod of ESE(Early Streamer Emission)and a conventional lightning rod.The results show that ESE rod performs similarly to conventional lightning rod,lacking the enhanced protective effects claimed by the manufacturers.
作者
裴哲浩
陈维江
陈家宏
殷禹
丁立键
傅中
张乔根
黄胜鑫
顾建伟
傅毓斐
樊星
章志远
PEI Zhehao;CHEN Weijiang;CHEN Jiahong;YIN Yu;DING Lijian;FU Zhong;ZHANG Qiaogen;HUANG Shengxin;GU Jianwei;FU Yufei;FAN Xing;ZHANG Zhiyuan(State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 710049,China;State Grid Corporation of China,Beijing 100031,China;State Grid Electric Power Research Institute Co.,Ltd.,Wuhan NARI,Wuhan 430074,China;China Electric Power Research Institute,Beijing 100085,China;School of Electrical Engineering and Automation,Hefei University of Technology,Hefei 230009,China;Electric Power Research Institute,State Grid Anhui Electric Power Company,Hefei 230001,China;State Key Laboratory of Advanced Electromagnetic Engineering and Technology,Huazhong University of Science and Technology,Wuhan 430074,China)
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2021年第11期3854-3862,共9页
High Voltage Engineering
基金
国家电网公司科技项目(SGTYHT/17-JS-199)。
关键词
非传统避雷针
雷击接闪效能差异
放电起始时刻
放电平均发展速度
迎面流注放电
迎面先导放电
non-conventional lightning rod
difference of lightning attractive efficiency
inception of discharge
average propagation speed of discharge
upward streamer discharge
upward leader discharge