摘要
目的对WOICE测量工具孕期问卷进行汉化并信效度检验,为孕期健康水平评估提供科学的测量工具。方法采用Brislin经典回译模型进行问卷汉化,并选取2020年9月1日至2021年3月30日于复旦大学附属妇产科医院进行产检的孕妇进行问卷调查。根据调查结果进行汉化问卷的信效度检验,信度检验用Cronbach′sα系数、折半信度和重测信度进行评价,效度检验主要评价内容效度和效标效度。结果本次研究回收有效问卷609份(98.5%);总问卷Cronbach′sα系数、折半系数和重测系数分别为0.780、0.751和0.792,生活功能损伤自评量表(WHODAS 2.0)、广泛性焦虑障碍量表(GAD-7)、简单自测抑郁量表(PHQ-9)、孕产疾患生理症状自报表各部分的Cronbach′sα系数均>0.8;除孕产疾患生理症状自报表的折半系数为0.686外,其余折半系数和重测系数均>0.7;相关分析显示WHODAS 2.0、GAD-7、PHQ-9各量表总得分与内部各条目得分具有正相关性,且差异具有统计学意义(r值分别介于0.463~0.696、0.566~0.763、0.480~0.792之间,P<0.05);对"水肿"和"体重增长过快"分别检验效标效度,结果显示关联系数为0.532和0.472,具有良好的效度。结论中文版WOICE测量工具孕期问卷在我国人群应用上有良好的信效度,可用于评价孕期妇女的孕产健康水平。
Objective To sinicize maternal WOICE tool: antenatal care, and to evaluate its reliability and validity, so as to provide a set scientific measurement tool for evaluating maternal health during pregnancy.Methods The Brislin classic back-translation model was used to translate the questionnaire into Chinese, and the questionnaire survey was conducted on pregnant women who had undergone an obstetric check-up at the obstetrics & gynecology hospital of Fudan University from September 1,2020 to March 30,2021.The reliability and validity of the questionnaire were evaluated accoriding to the survey results, Cronbach′s α,split-half reliability and test-retest reliability were used to evaluate the reliability, and validity mainly evaluated content validity and criterion validity.Results 609 valid questionnaires were collected with an effective rate of 98.5%.The Cronbach′s α coefficient, split-half reliability and test-retest reliability of the total questionnaire were 0.780,0.751 and 0.792,respectively.The Cronbach′s α coefficients of WHO Disability Assessment Schedule 2.0(WHODAS 2.0),Generalized Anxiety Disorder 7-item(GAD-7),Patient Health Questionnaire 9-item(PHQ-9) and the self-report of physical symptoms of maternal morbidity were all greater than 0.8.Except for the split-half reliability of the self-report of physical symptoms of maternal morbidity, which was 0.686,the rest of the split-half reliability and test-retest reliability of each part were all greater than 0.7.The correlation analysis showed the total scores of WHODAS 2.0,GAD-7 and PHQ-9 were positively correlated with the internal items, and the differences were statistically significant(r=0.463-0.696,0.566-0.763,0.480-0.792,respectively P<0.05).For criterion-related validity of “odema” and “rapid weight gain”,the correlation coefficients were 0.532 and 0.472,showing good validity.Conclusion The Chinese version of the maternal WOICE tool: antenatal care has good reliability and validity in the application of the Chinese population, and can be used to evaluate maternal health of pregnant women.
作者
陈美意
李昭润
顾春怡
钱序
CHEN Meiyi;LI Zhaorun;GU Chunyi;QIAN Xu(School of Public Health,Fudan University,Shanghai 200032,China;School of Public Health and Global Health Institute,Fudan University,Shanghai 200032,China;Department of Nursing,Obstetrics&Gynecology Hospital of Fudan University,Shanghai 200011,China)
出处
《中国妇幼健康研究》
2021年第11期1607-1612,共6页
Chinese Journal of Woman and Child Health Research
基金
国家自然科学基金资助项目(72004029)
上海市第五轮公共卫生体系建设三年行动计划重点学科资助项目(GWV-10.1-XK08)。