摘要
以湖北省鄂州市某污水处理厂实际工程为案例,通过分析半地下式污水处理厂地下箱体内人员值守情况和可燃物特性,探讨半地下式污水处理厂地下箱体的消防隐患,并结合现行消防规范,判定地下箱体火灾危险性级别,提出箱体消防设施要求,并进行实际工程的消防设施设计。
Through an engineering example of a sewage treatment plant in Ezhou city,the fire potential of underground tank of semi-underground sewage treatment plant are discussed based on the analysis of the staff on duty status and combustible substance property in the underground tank of semi-underground wastewater treatment plant(WWTP).Combined with the current fire protection code,the fire risk level of underground tank is analyzed.The requirements of the underground tank firefighting facilities are proposed,and the firefighting facilities design schemes is carried out.
出处
《环境保护与循环经济》
2021年第10期25-28,共4页
environmental protection and circular economy
关键词
半地下式污水处理厂
地下箱体
消防设施
semi-underground wastewater treatment plant
underground tank
firefighting facilities