为了在有限的容积率和用地面积指标下部署更多机柜,降低柴油发电机系统的建设成本,提升该系统的快速部署能力,在天津某数据中心采用室外布置4层集装箱式柴油发电机组的方案。通过CFD软件对方案进行仿真,结果表明室外4层集装箱式柴油发电机组技术上是可行的,能够为其他数据中心的柴油发电机组系统建设提供借鉴。
In order to deploy more cabinets under the limited plot ratio and land area indicators,while reducing the construction cost of the diesel generator system and improving the rapid deployment capability of the diesel generator system,a data center in Tianjin adopted an outdoor four-layer containerized diesel generator set scheme.The case is simulated through CFD simulation software,and the results show that the technical solution of the outdoor four�story containerized diesel generator set is feasible.This research can provide a reference for the construction of diesel generator set systems in other data centers.
作者
朱发熙
李雅宁
张仁玉
ZHU Faxi;LI Yaning;ZHANG Renyu(China Information Consulting&Designing Institute Co.,Ltd.,Nanjing 210019,China)
出处
《通信电源技术》
2021年第12期57-60,64,共5页
Telecom Power Technology