摘要
在建筑室内精装修中,室内大板块饰面墙砖采用传统的湿贴法施工容易出现空鼓、开裂等质量通病,且平整度难以控制。某项目室内大板块饰面墙砖采用干贴法,通过设置专用定位T形卡、锚固钉精确就位安装、基层精细化处理以及粉刷水泥砂浆层等组合控制方式,避免了质量通病的产生,且将平整度偏差控制在0.5 mm范围内,取得了理想的实施效果。
In the interior fine decoration of buildings,the traditional wet pasting method is used for the construction of indoor large plate decorative wall tiles,which is prone to common quality problems such as hollowing and cracking,and the flatness is difficult to control.The indoor large plate decorative wall tiles of a project adopt the dry pasting method.Through the combination control methods of setting special positioning T-cards,accurate positioning and installation of anchor nails,fine treatment of base course and painting cement mortar layer,the common quality problems are avoided,and the flatness deviation is controlled within 0.5 mm,and the ideal implementation effect is achieved.
作者
宋君勇
SONG Junyong(Hongxia Construction Co.,Ltd.,Wenzhou,Zheijiang 325000,China)
出处
《建筑施工》
2021年第11期2282-2284,共3页
Building Construction
关键词
大板块饰面墙砖
干贴法
平整度
定位T形卡
large plate decorative wall tiles
dry pasting method
flatness
positioning T-card