摘要 分析了中国近5a投运的燃煤电厂配套电除尘器的运行性能特征,对比了不同地区典型的1000MW机组电除尘器的关键性能数据,包括能耗、出口粉尘浓度、漏风率、压力降。结果表明:1000MW机组电除尘器单位发电量电耗占比为0.18%,低于600 MW机组的0.22%和300MW机组的0.3%,出口粉尘浓度实测大部分低于15mg/m^(3)且有多台低于10mg/m^(3)。对比了不同等级机组配套电除尘器的用钢量,1000MW机组电除尘器相比600MW的单位发电用钢量低约6%,相比300MW机组低约14%。 The operating performance characteristics of ancillary electrostatic precipitators(ESPs)in coal-fired power plants put into operation in the recent five years in China were analysed.The key performance data of ESPs for typical 1,000MW sets in various regions were compared including the energy consumption,ash concentration at outlets,air leakage rate and pressure drop.It has shown that the energy consumption of ESPs per unit power generation accounts for 0.18%of 1,000MW sets,lower than 0.22%of 600 MW sets or 0.3%of 300MW sets,whilst observed ash concentration at outlets being mostly less than 15 mg/m^(3) or even below 10 mg/m^(3).Comparing the steel material used to manufacture ESPs for different scale of sets,that for 1,000MW sets is about 6%less than that for 600MW sets and about 14%less than that for 300 MW sets.
作者 沈家栋 沈旭东 何东伟 赵海宝 俞云峰 蔡菊宇 Shen Jiadong;Shen Xudong;He Dongwei;Zhao Haibao;Yu Yunfeng;Cai Juyu(Zhejiang Feida Environmental Science&Technology Co.,Ltd.,Zhuji 311800;Zhejiang College,Tongji University,Jiaxing 314000;Jiaxing Vocational&Technical College,Jiaxing 314000;Jiaxing Environmental Monitoring Emergency and Accident Investigation Centre,Jiaxing 314000)
出处 《上海环境科学》 2021年第6期250-253,共4页 Shanghai Environmental Sciences
基金 国家重点研发计划(编号:2017YFB0603200)资助。
关键词 1000MW机组 燃煤电厂 超低排放 电除尘 运行特征 1,000 MW set Coal fired power plant Ultra-low emission Electric precipitation Operating characteristics
  • 相关文献

参考文献5

二级参考文献42

  • 1郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第十五届中国电除尘学术会议论文集.2013.
  • 2YOSHIO Nakayama,SATOSHI Nakamura,YASUHIRO Takeuchi,et al.MHI high efficiency system-proven technology for mul.
  • 3MASAMI Kato,TADASHI Tanaka,YASUKI Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA.
  • 4土屋喜重,川西好光,大西召一,等.Very cold electrostatic technology of advanced flue gas treatment system for co.
  • 5柳生隆志,土屋喜重,大西召一,等.Recent electrostatic precipitation technology[J].三菱重工技报,1996,33(1):69-73.
  • 6Development and demonstration of waste heat integration with solvent process for more efficient CO2 removal f.
  • 7柴田宪司,三重野光博,山本卓也.電気集麈方法[P].三菱重工技报.2000.
  • 8TOSHIAKI Misaka,YOSHIHIKO Mochizuki.Recent application and running cost of moving electrode type electrostati.
  • 9STEPHENL Francis,ANDREAS Back,PER Johansson.Reduction of rapping losses to improve ESP performance[C]//11th I.
  • 10森雄介,積田佳満,松本有夫,等.Operation results of IHI flue gas desulfurization system-unit No.1 (1 000 MW) of.

共引文献126

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部