摘要
We perform a systematic study on the effect of non-uniform track efficiency correction in higher-order cumulant analysis in heavy-ion collisions.Through analytical derivation,we find that the true values of cumulants can be successfully reproduced by the efficiency correction with an average of the realistic detector efficiency for particles with the same charges within each single phase space.The theoretical conclusions are supported by a toy model simulation by tuning the non-uniformity of the efficiency employed in the track-by-track efficiency correction method.The valid averaged efficiency is found to suppress the statistical uncertainties of the reproduced cumulants dramatically.Thus,usage of the averaged efficiency requires a careful study of phase space dependence.This study is important for carrying out precision measurements of higher-order cumulants in heavy-ion collision experiments at present and in future.
作者
司凡
张一飞
罗晓峰
Fan Si;Yifei Zhang;Xiaofeng Luo(State Key Laboratory of Particle Detection and Electronics,University of Science and Technology of China,Hefei 230026,China;Key Laboratory of Quark&Lepton Physics(MOE)and Institute of Particle Physics,Central China Normal University,Wuhan 430079,China)
基金
Supported by National Key Research and Development Program of China(2018YFE0205200,2018 YFE0104700,2020YFE0202002)
Natural Science Foundation of China(11890711,11890712,12122505,11828501,11861131009)
Anhui Provincial Natural Science Foundation(1808085J02)
Innovation Fund of Key Laboratory of Quark and Lepton Physics(QLPL2020P01)。