摘要
The system analysis of specific absorption rate(SAR)in human body exposed to a base station antenna by using finite difference time domain techniques was presented in this research works.The objectives of this work are to evaluate the knowledge and awareness about SAR among human body and mobile base station.The paper investigates the electromagnetic wave absorption inside a human body.The human body has been identified using dataset based on 2D object considering different electrical parameters.The SAR convinced inside the human body model exposed to a radiating base station antenna(BSA)has been considered for multiple numbers of carrier frequencies and input power of 20 W/carrier at GSM 900 band.The distance(R)of human body from BSA is varied in the range of 0.1 m to 5.0 m.For the number of carrier frequency equal to one and R=0.1 m,the concentrated value of whole-body average SAR obtained by FDTD technique is found to be 0.68 W/kg which decreases either with increase of R or decrease of number of carrier frequencies.Safety distance for general public is found to be 1.5 m for number of carrier frequencies equal to one.The performance accuracy of this analysis meets the high level condition by comparing with the relevant system development in recent time.
基金
This work is collaborative research with the Department of Electronics&Communication Engineering,Acharya Institute of Technology,Bengaluru,India.And also this work is a collaborative research between Yangon Technological University and University of Oulu in Finland based on the enhancement of Telecommunication Engineering Education in YTU.This work is fully supported by the government research funds of 2020-2021 academic year which is the grant no of GB/D(4)2020/4.