摘要
卷包车间空调机组实际运行时易出现空调参数控制精度过高、空调运行控制与生产设备的开启情况无法良好匹配等问题。在保证卷烟质量的前提下,根据实际工艺需求调整卷包车间空调参数控制精度。同时,通过增设风量控制调节阀和电动执行器、关闭闲置设备区域上方风口、优化空调机组控制策略等措施,实现空调机组布置和送风调节与设备生产良好匹配。监测数据显示,空调机组节能率达到28.9%。
In the actual operation of the air conditioning system in the package workshops,problems such as too high control accuracy of air conditioning parameters and failure to match the operation control of the air conditioning system with the opening of production equipment are prone to occur.On the premise of ensuring the cigarette quality,adjusts the control precision of air conditioning parameters in the package workshop according to the actual technological requirements.At the same time,by adding air flow control valves and electric actuators,closing the outlets above the idle equipment area,optimizing the control strategy of air conditioning units,the arrangement of air conditioning units and air supply regulation can be well matched with the production of equipment.Monitoring data shows that the energy saving rate of air conditioning units reaches 28.9%.
作者
刘敏
曾巍
陈晓春
郝军
蔡蓝燕
曾静
徐建燎
Liu Min;Zeng Wei;Chen Xiaochun;Hao Jun;Cai Lanyan;Zeng Jing;Xu Jianliao(China Urban Development Planning&Design Consulting Co.,Ltd.,Beijing,China;不详)
出处
《暖通空调》
2021年第12期87-91,共5页
Heating Ventilating & Air Conditioning
关键词
卷包车间
空调机组
控制精度
空调分区
送风优化
改造
风量调节
节能
package workshop
air conditioning unit
control precision
air conditioning zoning
air supply optimization
transformation
air rate regulation
energy saving