期刊文献+

机组定子振动幅值大原因分析和解决措施

Cause Analysis and Solution of Large Vibration Amplitude of Unit Stator
下载PDF
导出
摘要 针对彭水电站4号水轮发电机组定子振动幅值大的问题,通过4号机组A级检修,对机组相关部件进行调整,有效降低了定子振动幅值,确保了机组安全稳定运行,为后期水轮发电机组类似问题治理提供参考。 Aiming at the problem of large vibration amplitude of No.4 hydro generator unit stator in Pengshui hydropower station,through the class A maintenance of unit 4,the relevant components of the unit are adjusted to effectively reduce the vibration amplitude of the stator,ensure the safe and stable operation of the unit,which provides reference for the treatment of similar problems of water turbine generator units in the later stage.
作者 孙红武 SUN Hongwu(Chongqing Datang International Pengshui Hydropower Development Co.,Ltd.,Chongqing 409600,China)
出处 《电工技术》 2021年第21期1-2,36,共3页 Electric Engineering
关键词 水轮发电机组 定子振动轴线调整 转子圆度 turbine generatorunit stator vibration axis adjustment rotor roundness