目前通信基站能耗主要包括主设备能耗与制冷能耗,而制冷能耗占比约30%~40%。机房能耗大、能效水平低。文中分析了影响机房能效的关键因素及其影响机理,并寻求实现基站节能的有效途径。
At present,the energy consumption of communication base stations mainly includes the main equipment energy consumption and cooling energy consumption,and cooling energy consumption accounts for about 30%to 40%.The energy consumption of the computer room is large and the energy efficiency level is low.This paper analyzes the key factors that affect the energy efficiency of the computer room and its influencing mechanism,then seeks an effective way to achieve energy conservation in the base station.
作者
李奥
王未
刘绚
赵贺朋
李玉昇
LI Ao;WANG Wei;LIU Xuan;ZHAO Hepeng;LI Yusheng(China Mobile Group Design Institute Co.,Ltd.,Beijing 100080,China)
出处
《通信电源技术》
2021年第14期52-56,共5页
Telecom Power Technology
关键词
基站
能效
影响因素
节能
base station
energy efficiency
influencing factors
energy saving