摘要
以某19000TEU集装箱船加装混合式脱硫装置为对象,研究如何对中压配电系统进行技术改造。根据加装脱硫装置改造电力负荷分析,加装混合式脱硫装置用电设备多,用电负荷需求大,需要对原船中压配电板进行加屏改造,以满足加装脱硫装置用电负荷需求。
This paper takes the installation of a hybrid mode Exhaust gas cleaning system in a 19000 container vessel as the research object,and studies how to retrofit the medium-voltage electrical power system.According to the power loading analysis for the retrofitted of the EGCS,the installation of the hybrid EGCS requires a large power consumption and the original medium-voltage switchboard should be carried out additional panel modification to meet the requirement of the retrofitted for EGCS(Exhaust Gas Cleaning System).
作者
何守安
袁姗
张鹏
谭凉
何苏婷
He Shouan;Yuan Shan;Zhang Peng;TanLiang;He Suting(Guangzhou Wenchong Dockyard Co.,Ltd.,Guangzhou 511462)
出处
《广东造船》
2021年第6期83-85,82,共4页
Guangdong shipbuilding