摘要 运动平板试验是一种可用于判断冠状循环功能的无创检查方法。GE CASE运动测试系统拥有先进的诊断及安全评估工具,安全可靠,使用方便。文章详细介绍了GE CASE运动测试系统的原理、性能特点和临床应用,分析了运动测试系统黑屏故障的原因并提出解决方案,对其检修过程进行分析,以期为临床使用提供更有力的支持。 Electrocardiographic exercise testing is a noninvasive test that can be used to determine coronary circulation function.GE CASE exercise testing system is safe and easy to use with advanced diagnostic and safety assessment tools.The principle,performance characteristics and clinical application of GE CASE exercise testing system are introduced in detail.This paper analyzes the causation of the black screen fault of the exercise test system and puts forward solutions.Hopefully,through the analysis of its maintenance process,the content can provide more powerful support for related clinical work.