期刊文献+

Improving the seismic performance of base-isolated liquid storage tanks with supplemental linear viscous dampers 被引量:2

下载PDF
导出
摘要 Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第1期269-282,共14页 地震工程与工程振动(英文刊)
  • 相关文献

参考文献6

二级参考文献63

  • 1Kenneth K. Walsh Makola M. Abdullah.Adaptive base-isolation of civil structures using variable amplification[J].Earthquake Engineering and Engineering Vibration,2006,5(2):223-233. 被引量:3
  • 2Abali E and Uckan E (2009), "Parametric Analysis of Liquid Storage Tanks Base Isolated by Curved Surface Sliding Bearings," Soil Dynamics and Earthquake Engineering, 30(1-2): 21-31.
  • 3API (2009), "Welded Steel Tanks of Oil Storage," N.W., Washington D.C., American Petroleum Institute.
  • 4Bachmann H and Wenk T (2000), "Softening Instead of Strengthening for Seismic Rehabilitation," International Structural Engineering, 10(1): 61-65.
  • 5Boduroglu MH, Timur T and Timur SC (2006), "Evaluation of Seismic Safety of Liquid Storage Tanks and Application of Base Isolation System," Report No. ICTAG 1587/MAK(1021054), OCAK, Ystanbul.
  • 6Chalhoub MS and Kelly JM (1990), "Shake Table Test of Cylindrical Water Tanks in Base-isolated Structures," Journal of Engineering Mechanics, 116(7): 1451-1472.
  • 7Christovasilis IP and Whittaker AS (2008), "Seismic Analysis of Conventional and Isolated LNG Tanks Using Mechanical Analogs," Earthquake Spectra, 24(3): 599-616.
  • 8Constantinou, MC, Tsopelas P, Kasalaniti A and Wolff ED (1999), "Property Modification Factors for Seismic Isolation Bearings," Report No. MCEER 99-0012, Multidisciplinary Center for Earthquake Engineering Research, State University of New York at Buffalo, Buffalo, NY.
  • 9Dunkerley S (1894), "On the Whirling and Vibration of Shafts," Philosophical Transactions of the Royal Society of London, 185: 279-360.
  • 10Fenz DM and Constantinou MC (2006), "Behaviour of the Double Concave Friction Pendulum Bearing," Earthquake Engineering & Structural Dynamics, 35(11): 1403-1424.

共引文献33

同被引文献22

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部