期刊文献+

SG45圆钢超声波探伤不合格原因分析及工艺改进

Analysis on Disqualification Causes and Process Improvement of SG45 Round Steel in Ultrasonic Flaw Detection
下载PDF
导出
摘要 通过便携式超声波探伤仪、金相显微镜、扫描电镜和直读光谱仪对大规格SG45圆钢超声波探伤不合格原因进行分析。结果表明,圆钢超声波探伤不合格是由于圆钢心部存在组织偏析。通过调整连铸电磁搅拌参数、轻压下工艺和连铸坯缓冷,同时优化轧制工艺可以提升大规格SG45圆钢超声波探伤合格率。 The unqualified cause of ultrasonic flaw detection for large-size SG45 round steel was analyzed by portable ultrasonic flaw detector,metallographic microscope,scanning electron microscope and direct reading spectrometer.The results showed that the unqualified ultrasonic flaw detection of SG45 round steel was due to the structural segregation in the core of the round steel.By adjusting continuous casting electromagnetic stirring parameters,light reduction process,slow cooling of continuous casting billet and optimizing rolling process,the the qualified rate of ultrasonic flaw detection for large-size SG45 round steel can be improved.
作者 钟芳华 刘年富 黄铸铭 吴学兴 钟凡 ZHONG Fang-hua;LIU Nian-fu;HUANG Zhu-ming;WU Xue-xing;ZHONG Fan(Baowu JFE Special Steel Co.,Ltd.,Shaoguan Guangdong 512123,China)
出处 《热处理技术与装备》 2021年第6期40-44,共5页 Heat Treatment Technology and Equipment
关键词 SG45 超声波探伤 组织偏析 SG45 ultrasonic flaw detection structural segregation
  • 相关文献

参考文献8

二级参考文献49

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部