摘要
基于配电网故障点上游多级开关同时跳闸情况,提出了集中式馈线自动化故障定位分析及判断。重点阐述了配电终端装置保护信息汇总与分析、多级开关跳闸情况的馈线自动化故障定位逻辑及应用。
Based on the simultaneous tripping of the upper-level multi-level of the fault point in distribution network,the centralized feeder automatic fault location analysis and judgment are proposed.The logic and application of feeder automation fault location for distribution terminal unit protection information aggregation and analysis,and multi-level switch trip are mainly introduced.
作者
张卫星
马翔
ZHANG Weixing;MA Xiang(NARI Group Corporation,Nanjing 211106,China;NARI Technology Development Co.,Ltd.,Nanjing 211106,China)
出处
《电工技术》
2021年第23期55-56,共2页
Electric Engineering
关键词
配自系统
集中式馈线自动化
多级跳闸
故障定位
distribution automation system
centralized feeder automation
multi-level trip
fault location