期刊文献+

离子色谱法测定塑料中卤素准确性研究 被引量:1

Study on Accuracy of Ion Chromatography for Determination of Halogens in Plastics
下载PDF
导出
摘要 利用氧弹燃烧-离子色谱法测定塑料样品中的卤素含量。研究了氧弹燃烧过程中不同的处理条件(吸收液浓度、样品质量、吸收时间等)对卤素含量测试结果准确性的影响。结果表明:在最佳前处理条件下,卤素含量相对标准偏差不超过5.0%,其加标回收率97.5%~104.5%,满足测试要求。 The oxygen bomb combustion-ion chromatography was used to determine the halogen content in plastic samples.The effect of different treatment conditions(absorbent solution concentration,sample quality,absorption time,etc.)on the accuracy of the halogen content test results during the oxygen bomb combustion process was studied.The results show that under the best pre-treatment conditions,the relative standard deviation does not exceed 5.0%,and the standard addition recovery rate is from 97.5%to 104.5%,which meets the test requirements.
作者 何晓俊 刘奇祥 庞承焕 吴博 叶南飚 He Xiaojun;Liu Qixiang;Pang Chenghuan;Wu Bo;Ye Nanbiao(National Ploymer Materials Industry Innovation Center Co.,Ltd.,Guangzhou,Guangdong,510663;Enterprise Technology Center of Kingfa Science & Technology Co., Ltd., Guangzhou,Guangdong,510663;National Engineering Laboratory for Plastic Modification and Processing,Guangzhou,Guangdong,510663)
出处 《现代塑料加工应用》 CAS 2021年第6期32-34,共3页 Modern Plastics Processing and Applications
基金 国家重点研发计划项目(2019YFF0216903)。
关键词 氧弹燃烧 离子色谱 卤素 影响因素 oxygen bomb combustion ion chromatography halogen factor
  • 相关文献

参考文献2

二级参考文献12

共引文献16

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部