两档变容定速压缩机提升空调器SEER实验研究 被引量:1

Experimental research on air-conditioner SEER improvement by 2-stage capacity fixed-speed compressor
下载PDF
导出
摘要 定速空调器低负荷工况频繁启停会造成能量损失,为提高SEER,可采用两档变容技术降低压缩机的启停频率,达到节能的目的。以印度市场为例,通过在家用空调器上搭载一种具有两档变容能力的定速压缩机,进行空调器性能测试,然后根据印度气候及年运行时间计算出SEER,并与其作为常规一档能力定速空调器的SEER进行比较,结果表明两档变容定速空调器SEER提升可达15%。 Two-stage capacity Air conditioner can save more energy by improving SEER,through reducing compressor on/off frequency at low load conditions.By installing a 2-stage capacity compressor in an air conditioner unit,testing the performance and calculating the SEER according to the Indian climate temperature bin hours and ISO 16358-1-2013 standard,concluded that the SEER of the air conditioner unit as 2-stage capacity air conditioner can be improved approximately 15%higher than that of the unit as fixed single capacity air conditioner.
作者 廖四清 区永东 曾令华 卢耀汕 LIAO Siqing;OU Yongdong;ZENG Linghua;LU Yaoshan(Guangdong Meizhi Compressor Limited,Foshan 528000)
出处 《家电科技》 2021年第6期52-55,共4页 Journal of Appliance Science & Technology
关键词 定速压缩机 空调器 两档变容 SEER Fixed-speed compressor Air-conditioner 2-stage capacity SEER