摘要
结合标准及现场操作实践中的应用,介绍了正压同步电动机电抗、时间常数等参数测定的方法和注意事项,以期通过试验方法得到较为准确的测量值。
Pressurized synchronous generator is a kind of explosion proof equipment with pressurized housing,which makes inner protective gas pressure higher than outer atmospheric pressure.It has great advantages and development prospects in the application of large explosion proof motor structure.Its main parameters,such as reactance and time constant,are very important in the power system operation.In combination with the application of standard and field operation practice,it introduces the parameter measurement method and matters needing attention,in order to obtain more accurate measurement value through the test method.
作者
高渊
黄长铎
Gao Yuan;Huang Chang-duo(Wolong Electric Nanyang Explosion Protection Group Co.,Ltd.,Nanyang Henan 473008)
出处
《电气防爆》
2021年第6期12-15,共4页
Electric Explosion Protection
关键词
直轴瞬态电抗
直轴超瞬态电抗
时间常数
零序电抗
负序电抗
direct axis transient reactance
direct axis subtransient reactance
time constant
zero sequence reactance
negative sequence reactance