摘要 Reliablemicrostructuremeasurement of snow is a requirement for microwave radiative transfer model validation.Snow specific surface area(SSA)can be measured using stereological methods,in which snow samples are cast in the field and photographed in the laboratory.Processing stereology photographs manually by counting intersections of test cycloids with air-ice boundaries reduces the problems in binary segmentation.This paper is a case study to evaluate the repeatability of the manually stereology interpretation by two independent research groups.We further assessed how uncertainty in snow SSA influences simulated brightness temperature(TB)driven by the Microwave Emission Model of Layered Snowpacks(MEMLS),and how stereology compares to Near Infrared(NIR)camera and hand lens.Data was obtained from two alpine snow profiles from Steamboat Springs,Colorado.Results showed that stereological SSA values measured by two groups are highly consistent,and the ground radiometer measured T_(B)at 19 and 37 GHz was successfully predicted(RMSE<3.8 K);simulations using NIR SSA and hand-lens geometric grain size(Dg)measurements have larger errors.This conclusion was not sensitive to uncertainty in the free parameters of TB modeling.
出处 《International Journal of Digital Earth》 SCIE 2021年第10期1316-1336,共21页 国际数字地球学报(英文)
基金 supported by NASA Terrestrial Hydrology Program[grant number NNX09AM10G] Strategic Priority Research Program of Chinese Academy of Sciences[grant number XDA20100300].