摘要 航空安全一直是航空行业发展中的重要课题,降低航空电气系统的火灾危险性可以有效提高飞机的飞行可靠性。首先分析航空电路特点,其电源相比地面来说,电压大小为110 V,频率为400 Hz;其次用Matlab/Similunk仿真模块建立Cassie电弧故障模型,对纯阻性负载和阻感性负载进行串联电路仿真;最后得出时域电流、电压波形,并进行特征分析。 Aviation safety has always been an important issue in the development of the aviation industry.Reducing the fire hazard of aviation electrical systems can effectively improve the flight reliability of aircraft.First,analyze the characteristics of aeronautical circuits.Compared with the ground,the power supply has a voltage of 110 V and a frequency of 400 Hz;secondly,a Cassie arc fault model is established with the Matlab/Similunk simulation module,and the pure resistive load and the resistive inductive load are connected in series.Simulation;finally get the time-domain current and voltage waveforms,and perform characteristic analysis.
作者 关磊 曲娜 姚泽洋 王子天 庄睿晨 GUAN Lei;QU Na;YAO Zeyang;WANG Zitian;ZHUANG Ruichen(School of Safety Engineering,Shenyang Aerospace University,Shenyang Liaoning 110136,China)
出处 《信息与电脑》 2021年第22期47-49,共3页 Information & Computer
基金 沈阳航空航天大学创新创业训练项目(项目编号:X202010143154)。
关键词 航空电弧故障 负载条件 Similunk仿真 Cassie电弧模型 aviation arc fault load condition Similunk simulation Cassie arc model
  • 相关文献

参考文献11

二级参考文献52

  • 1蔡彬,陈德桂,吴锐,王鑫伟,高冬梅,陈卫国.开关柜内部故障电弧的在线检测和保护装置[J].电工技术学报,2005,20(10):83-87. 被引量:80
  • 2谈勇.飞机线路故障问题及其对策[J].航空维修与工程,2006(2):62-63. 被引量:18
  • 3陈德桂.低压电弧故障断路器——一种新型低压保护电器[J].低压电器,2007(3):7-9. 被引量:39
  • 4CHANDRASEKARAN S,SMITH P.Aircraft electrical system monitoring with arc fault circuit protection and automatic fault location[C] //SAE Power Systems Conference,August 2006.
  • 5BLUMER J,ROGOVIN D.Advanced vehicle wire health for the 21st century[C] //Power System Conference Reno,Nevada,November 2-4,2004.
  • 6PAUL K K,CYNTHIA F,PAUL S.Locating hidden hazards in electrical wiring[C] //Aged Electrical Systems Research Application Symposium,October 18-19,2006,Chicago,Illinois.
  • 7SIDHU T S,SINGH G,SACHDEV M S.A new technique for detection and locationg of arcing faults in power system apparatus[C] //Electrical and Computer Engineering,1998 Canada.IEEE Canadian Conference:Vol.1,May 24-28,1998:185-188.
  • 8SIDHU T S,SINGH G,SACHDEV M S.Protection of power system apparatus against areiag faults[C] //1998 IEEE Region 10th International Conference on Global Connectivity in Energy,Computer,Communication and Control:V01.2,Dec 17.19,1998,New Delhi,India.USA:IEEE,1998:436-439.
  • 9SIDHUT S,SACHDEV M S,SAGoo G S.Detection and location oflow-level arcing faults in metal-clad electrical apparatus[C] //Seventh International Conference on Developments in Power System Protection.Conference.Publication No.479,April 9-12,2001,Amsterdam;Netherlands.London:IEE.2001:157-160.
  • 10SIDHUT S,SAGOO G S,SACHDEV M S.Multisensor secondary device for detection of low-level arcing faults in metal-clad MCC switchgear panel[J] //IEEE Transactions on Power Delivery,2002,17(1):129-134.

共引文献129

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部